Objective
Provide the DIO wiring diagram for QCX/MTC controller to all users with Integrated DIO.
Procedure
Click here to view and download the wiring diagram.
Notes
--The Integrated DIO bank only supports a single tool on a multi tool controller. If DIO is needed for additional tools, External DIO has to be used (QC-DIO-8CH).
--Below are the specifications for the Integrated Inputs and Outputs. External DIO may be necessary if the Output Loads require more than the combined 200mA max.
Digital Inputs:
Input Operating Range: -3 – 30V
Logic High: 11V+
Logic Low: =<5V
Input Current 6.5 – 9.5mA
Digital Outputs:
Source Current (Internal Supply): 200mA max total combined outputs used