The Ingersoll Rand® INSIGHTqcx™ controller supports programming compatible tools, managing fastening Jobs, configuring process controls, and recording results.
Use this article to follow the setup workflow. For communication problems, unexpected tool behavior, or log collection, see Troubleshooting the INSIGHTqcx Controller.
Applicability: The accompanying video primarily demonstrates legacy QX tools using the controller’s radio interface on a multi-tool configuration. Pairing methods, menus, licenses, and available features depend on the controller, tool, and installed software. Follow the applicable IR instructions for other configurations, including Wi-Fi tools.
Safety Notice
Follow the applicable controller, tool, and accessory safety instructions. Only authorized personnel should change fastening parameters, interlocks, network settings, or external controls.
Validate changes before returning equipment to production.
Note: Energy scans interrupt communication with tools. Perform them during a planned production stop.
Before You Begin
Confirm the following:
- Controller model, software version, and installed licenses
- Tool models, firmware versions, and communication method
- Login credentials with configuration permissions
- Approved fastening strategies, targets, units, and limits
- Required Job sequences, batch counts, and interlocks
- Job-selection source
- Required accessories and I/O assignments
- Network and integration settings supplied by the responsible personnel
Tools & Materials
- Installed INSIGHTqcx controller
- Compatible tools with charged batteries
- Computer and Ethernet connection, if using browser access
- Applicable tool USB cable
- Compatible accessories and cables, as required
- Applicable IR manuals and software release notes
Setup and Configuration Video
Note: The video’s IP addresses, channels, fastening targets, and timing values are demonstration examples. Use settings approved for the application.
Viewing note: The video begins with setup and configuration. Troubleshooting begins at approximately 01:29:30. See Troubleshooting the INSIGHTqcx Controller.
Procedure
1. Confirm Connections and Log In
For the external-radio configuration shown, leave the USB radio module connected. It provides communication with the radio-connected tools.
Access the controller through its touchscreen, if equipped, or a computer browser using its configured IP address.
Confirm the correct network port and addressing before connecting, particularly where an interface is used for plant or Fieldbus communication. Log in using an authorized account.
2. Verify Firmware Compatibility
- Check the controller and tool versions.
- For the demonstrated USB compatibility check, install a charged tool battery and power on the tool.
- Connect it to an available controller USB port.
- Review compatibility messages.
- Follow the applicable IR update instructions if needed.
3. Configure Basic Settings
Verify:
- Date, time, and time zone
- Network settings
- Station or system identification, where used
- User accounts and permissions
Correct time settings help correlate results and diagnostic records.
4. Configure Radio Communication, If Applicable
For the legacy-radio workflow demonstrated:
- Open Diagnostics > Energy Scan during a planned stop.
- Review channel activity at the actual operating location.
- Open Wireless Tools > Radio Settings, or the wireless shortcut.
- Select the appropriate channel and power level.
- Apply the settings.
Repeat the assessment when moving equipment from a tool crib to production. Keep paired tools powered when applying radio changes and check each tool’s update status.
Use the applicable network instructions for Wi-Fi configurations.
5. Pair and Identify the Tools
- Open the wireless-tool pairing interface.
- Put the controller and tool into pairing mode using the applicable instructions.
- Confirm that the tool appears.
- Close pairing when finished.
- Use Find Me, where available, to identify the physical tool.
- Give the tool a meaningful station or application name.
Confirm that the installed license supports the required number of tools.
See Pairing QX Tools to Ingersoll Rand Cordless Controllers.
6. Create and Save the Psets
A Pset defines fastening parameters. A Job combines Psets with the sequence and process controls required for an operation.
- Open Menu > Pset.
- Select the appropriate tool context.
- Add or edit a Pset.
- Enter its name and confirm the units.
- Configure the required steps, strategy, target, limits, and speeds.
- Select Save Step.
- Return to the main Pset screen and save the Pset.
Scroll if necessary to reach Save Step on the touchscreen. Review associated limits after changing a target.
Selecting a tool while creating a Pset checks compatibility; it does not by itself assign the Pset to that tool.
7. Create and Assign the Job
- Open Menu > Job and the Job list.
- Create or edit a Job and enter its name.
- Add the required Psets.
- Configure batch counts, sequence rules, and the Job-completion point.
- Configure required interlocks.
- Save the Job.
- Assign it to the intended tool.
- Confirm the assignment.
A saved Job must be assigned to the tool before it can be used in the demonstrated workflow.
See Creating a Pset and Job Using an MTC Controller.
8. Configure Job Selection and Interlocks
Choose the selection source required by the application, such as the controller, tool display, barcode, protocol, or external I/O.
Configure the applicable Job interlocks:
- Valid Job: Requires a new Job selection after completion.
- Barcode: Requires the configured barcode conditions.
- Tool Enable: Supports the application’s external enable/disable control.
- Smart Socket: Requires the socket assigned to the active Pset.
- Disable Reverse: Prevents reverse operation where required.
Test both permitted operation and the conditions that should prevent operation.
9. Configure Accessories and External Controls
For the QC-SKTR USB socket tray:
- Connect and name the accessory.
- Open Digital I/O and select the tray as the source for the intended tool.
- Assign the required socket inputs and outputs.
- Enable Smart Socket in the Job.
- Assign the required socket to each applicable Pset entry.
- Save and test.
Socket-based Job selection and Smart Socket interlocking serve different purposes. Follow the dedicated socket-tray setup instructions.
For external communications, verify unique connection settings, barcode sources, PLC mappings, and enable/disable behavior with the controls integrator.
10. Validate and Back Up the Configuration
- Select the assigned Job through the configured source.
- Run the approved validation process.
- Check Pset progression, batch counts, failure rules, and interlocks.
- Review Results > Cycle Results and required identifiers.
- Verify trace capture and transfer behavior, if used.
- Complete tool backups before creating the controller backup, as demonstrated.
- Download and retain the controller backup.
Requiring complete trace transfer can delay the next cycle. Validate trace requirements against production timing.
Expected Tool Behavior
After setup:
- The intended tool communicates with the controller.
- The assigned Job can be selected through the configured source.
- Required interlocks control operation.
- Psets and batch counts follow the approved sequence.
- Results contain the expected tool, Job, Pset, and identifiers.
If behavior differs, see Troubleshooting the INSIGHTqcx Controller.
When to Contact Technical Support
Contact Ingersoll Rand when compatibility, licensing, configuration, or integration requirements cannot be confirmed, or when validation fails.
Submit a request to Ingersoll Rand Technical Support.
Manuals & Downloads
- INSIGHTqcx Product Information Manual
- Communication Module Safety Information — 24074205
- INSIGHTqcx Documentation
- INSIGHT Control — Latest Global Releases
- Pairing QX Tools to Ingersoll Rand Cordless Controllers
- Replacing a QX Tool on an MTC Controller
Need Help?
If assistance is needed in the product selection process, please contact Ingersoll Rand's Power Tool Technical Support Team through Submit a Request via our Help Center, email at IRToolHelp@irco.com, or call us at 800-TOOL-HLP (800-866-5457).
Comments