Use this article to investigate communication problems, unexpected tool-enable conditions, configuration changes, and missing results on an Ingersoll Rand® INSIGHTqcx™ controller.
For initial programming and configuration, see Setting Up and Configuring the INSIGHTqcx Controller.
Applicability: The accompanying video primarily demonstrates legacy radio-connected QX tools. Use diagnostics and instructions applicable to the actual controller, tool, communication method, and software version.
Safety Notice
Follow the applicable equipment safety instructions. Coordinate troubleshooting with production personnel before changing communication settings or testing tool operation.
Note: Energy scans interrupt tool communication. Run them only during a planned production stop.
Collect relevant logs before clearing diagnostic records, performing a factory reset, or making changes that could remove evidence of the problem.
Before You Begin
Record:
- Controller and affected tool models and serial numbers
- Installed software and firmware versions
- Communication method
- Exact symptom or displayed message
- Time of occurrence, including time zone
- Whether one tool or multiple tools are affected
- Recent configuration, equipment, or network changes
Tools & Materials
- Authorized controller login
- Computer and suitable connection, if needed
- Applicable tool USB cable
- Access to the installed version’s release notes
- Means of saving logs, screenshots, and results
Troubleshooting Video
Viewing note: Advance to approximately 01:29:30 for troubleshooting. Earlier sections demonstrate setup and configuration. See Setting Up and Configuring the INSIGHTqcx Controller.
Procedure
1. Identify the Symptom
Determine whether the problem concerns:
- Tool-to-controller communication
- A tool that communicates but will not run
- Incorrect Job or Pset behavior
- Accessories or external controls
- Missing results or traces
This distinction helps identify the next check.
2. Review Recent Changes
Open the Audit Log and look for changes near the reported failure time. Review the changed field, previous and new values, and logged-in user where available.
Use the Event Log to correlate events such as USB connections, tool disconnections, or restore operations. An event entry does not necessarily indicate a fault.
3. Check Communication
Confirm tool power, battery condition, pairing, and firmware compatibility.
For the external-radio configuration shown in the video, confirm that the USB radio module remains connected.
For radio-related problems:
- Keep the tool awake.
- Open Wireless Diagnostics.
- Review received signal strength at the actual working positions.
- Check for changes in distance, obstructions, or nearby wireless equipment.
- If needed, perform an energy scan during a planned stop.
In the demonstrated diagnostics, RSSI values closer to zero indicate stronger received signals. The video’s example readings are not universal acceptance limits.
After a radio-channel change, check that each tool received the update. The video demonstrates a USB settings-update method for a tool that missed the change.
For Wi-Fi tools, use the applicable network and pairing instructions.
4. Check Job Assignments and Enable Conditions
If the tool communicates but will not run, verify:
- The required Job is assigned to that tool.
- A valid Job is selected.
- The configured Job-selection source matches the actual source.
- Barcode requirements are satisfied.
- The correct socket is selected when Smart Socket is enabled.
- Required external enable signals are present.
- Maintenance alarms or other configured conditions are not disabling operation.
A communication connection alone does not establish that the tool is enabled.
Use Setting Up and Configuring the INSIGHTqcx Controller to review the configuration workflow.
5. Check Results and Traces
Open Results > Cycle Results.
Check the selected tool, date/time range, filters, Job, Pset, and identifiers before concluding that data is missing.
For incomplete traces, review capture and transfer settings. In the demonstrated system, a new cycle can interrupt a pending trace transfer unless complete transfer is required. Requiring complete transfer can increase the time before the next cycle.
6. Check Accessories and External Communications
For socket-tray problems, verify recognition of the accessory, I/O assignments, the Job’s Smart Socket interlock, and socket assignments.
For PLC or protocol problems, have the controls integrator check:
- Connection addresses and unique ports
- Selected Job source
- Enable/disable handling
- Input/output mappings
- Barcode handling
- Result-detection logic
The video warns that an In Cycle notification can be missed in the demonstrated legacy-radio system. Do not use it as the sole indication that new results are available.
7. Collect Diagnostic Information Promptly
Save the information relevant to the failure:
- System and debug logs
- Communication logs for the affected protocol
- Audit and event logs
- Tool fault history
- Relevant results and traces
Record the failure time and actions taken. Collect logs promptly because records may rotate or be overwritten.
8. Review Release Notes Before Further Changes
Compare the symptom with the installed version’s known issues and fixes.
Use the applicable update instructions if a software change is needed. Preserve configuration backups and diagnostic evidence before proceeding.
Do not use a factory reset as an initial troubleshooting step. The video describes it as clearing configuration, paired tools, and stored results.
Expected Tool Behavior
After resolving the problem:
- Communication remains stable in the intended operating area.
- The correct Job and Pset are active.
- Required interlocks enable and disable operation as intended.
- Accessories and external controls behave according to the approved process.
- Expected results and identifiers are recorded.
When to Contact Technical Support
Contact Ingersoll Rand when:
- Communication remains unreliable after basic checks.
- Compatibility or the update path is unclear.
- Configuration and enable conditions appear correct but operation remains blocked.
- Results are missing or incorrect.
- Backup, restore, or firmware operations fail.
- A fault requires additional diagnostic instructions.
Provide the recorded equipment details, failure time, reproduction steps, screenshots, logs, and changes already attempted.
Submit a request to Ingersoll Rand Technical Support.
Manuals & Downloads
- INSIGHTqcx Product Information Manual
- Communication Module Safety Information — 24074205
- INSIGHTqcx Documentation
- INSIGHT Control — Latest Global Releases
- Pairing QX Tools to Ingersoll Rand Cordless Controllers
- Replacing a QX Tool on an MTC Controller
Need Help?
If assistance is needed in the product selection process, please contact Ingersoll Rand's Power Tool Technical Support Team through Submit a Request via our Help Center, email at IRToolHelp@irco.com, or call us at 800-TOOL-HLP (800-866-5457).
Comments
0 comments