IQI Software Release Notes — Control Box Application v1.0.0.273
Last updated: December 8, 2025
Introduction
This release note covers the IQI11-FM Controller and Remote Browser software update. It includes software version details, tool compatibility, connectivity support, new features and enhancements, and upgrade instructions.
Important:
- Update both the controller and tool firmware versions.
- Please update all tools and controllers in the field to this firmware version.
1. Release Information
IQI Controller Software
| # | Description | Version |
|---|---|---|
| 1 | Application Version | 1.0.0.273 |
| 2 | Database Version | 3.46.1 |
| 3 | OS Version | 6.6.31.8 |
| 4 | Controller Version | 1.0.0.44 |
| 5 | Remote Browser Version | 1.0.0.257 |
Tool Firmware
| # | Description | Version |
|---|---|---|
| 1 | Communication Version | 1.0.16.0 (IQI2L Series) 1.0.42.0 (IQI4L Series) |
| 2 | BLDC Motor Version | 1.0.16.0 (IQI2L Series) 1.0.42.0 (IQI4L Series) |
2. New Features and Enhancements
New Features
-
Profinet Certification: Tests passed, certification completed and certificate issued. New GSDML file:
GSDML-V2.43-IngersollRand-InsightQI-20251021.xml.
Link: -
Ethernet IP Setup: New EDS file:
20251125_INSIGHTqiEIP3_4_20.eds.
Link: Fieldbus Connectivity: Now supported on both Port 1 and Port 2 (previously Port 1 only) for enhanced integration flexibility. - New Unit — inch‑ounces: Adds support for inch‑ounces unit of measurement for PSET setup, expanding flexibility for applications using this unit.
-
Global Settings — “Persist IO state on disconnect”: Controls job selection behavior when communication is lost while Interlock and job selection over that communication are enabled.
- Default (Non‑Persistent): Job is unselected; must be re‑selected after reconnection.
- Enabled (Persistent): Job remains selected after communication is restored.
- Factory Reset: Modified to retain Profinet Settings.
- Tool Overheat Protection: Added software safeguard; monitors temperature and stops operation when overheating is detected.
- IQ Stop: Algorithm enhanced to restrict torque overshoot on hard joints, improving tightening accuracy and process control for critical fastening.
Enhancements
- Ethernet IP Stability: Resolved frequent disconnections between IQI and Omron PLC NX1P2.
- Ethernet Cable Handling: Fixed issue where unplugging the Ethernet cable caused the controller to restart.
- EthernetIP Feedback: Corrected problem where EthernetIP could not return job selection and Incycle status.
- Controller Login: Addressed issue requiring a reboot after unplugging Ethernet cable without logout.
- PLC Integration: Fixed Ethernet IP connectivity issue with customer PLC.
- PFOP: Corrected issue where the controller restarted when MES sent an empty or incorrect barcode via PFOP.
- Ethernet Settings: After factory reset, Ethernet settings now remain as previously programmed.
- Multi‑Step PSET: Resolved issue where exceeding torque high limit on the second step (angle step) did not display OK/NOK and Incycle at IO was not reset.
- Upgrade Progress Indicator: During controller upgrades via the web browser, the local screen now displays a progress bar.
- Download Cycle Results (Remote Browser): Fixed problem where users were unable to download cycle results from the web interface.
3. Controller Upgrade Instructions
SendSafely
Controller versions are available via SendSafely:
- Ensure you update both the controller firmware version and the tool firmware version.
4. Revision History
| Application Version | Date | Summary of Changes | Author |
|---|---|---|---|
| 1.0.0.254 | 08/13/2025 | New features and issue resolution | Swathi Murali |
| 1.0.0.265 | 10/14/2025 | New features and issue resolution | Swathi Murali |
| 1.0.0.273 | 12/08/2025 | New features and issue resolution | Swathi Murali |