IQI11-FM Software Release™ Controller and Remote Browser
Applicon Version: 1.0.0.309
Release Date: November 18, 2026
This article provides detailed release notes for the latest global software release for IQI Series controllers, tools, and remote browser applications.
Important:
****Please ensure you are updating both the controller and the tool firmware versions****
Upgrade prerequisite: Controllers running an Application Version earlier than 1.0.0.282 must first be upgraded to 1.0.0.282 before upgrading to 1.0.0.309.
Release Information
The following software releases are launched as part of this release package.
| IQI Controller Firmware (.ecir) | ||
| # | Description | Version |
| 1 | Application Version | 1.0.0.309 |
| 2 | Database Version | 3.46.1 |
| 3 | OS Version | 6.6.31.8 |
| 4 | Controller Version | 1.0.0.51 |
| 5 | Remote Browser Version | 1.0.0.281 |
| IQI Tool Firmware (.etir) | |||
| # | Description | IQI2L Series | IQI4L Series |
| 1 | Communication Version | 1.0.25.0 | 1.0.52.0 |
| 2 | BLDC Motor Version | 1.0.25.0 | 1.0.52.0 |
New Features and Issues Resolved
New Features
- Tare Compensation Calculation: The torque in the cycle result now subtracts the Tare Compensation value. A new "Peak Torque" field stores the peak torque in the database.
Issues Resolved
- Downshift Speed Parameter: The Downshift Speed parameter can now be edited from the Controller UI.
- Barcode Criteria Job Name: Fixed an issue where the barcode criteria kept the old Job Name after the user edited or deleted it.
- Tool Calibration Start Button: Fixed the Start button on the Tool Calibration page, which didn't change state when a tool was hot-swapped.
- PFOP Enable Tool: Fixed an issue where Enable Tool failed when torque was below the threshold.
- MID 0035 Job Communication: MID 0035 job communication now works correctly.
- Invalid Job Selection: Fixed invalid job selection through Barcode/VIN and PFOP.
- Accessory Listing: Connected accessories now show up in the Accessories list.
- MID 0015 Response: The controller now generates and sends the expected MID 0015 response.
- Invalid Job Handling: The Local UI no longer lets users select and run an invalid job, and the batch count no longer updates for invalid jobs.
Motor Brake Optimization for IQI4 Series Tools - This a one-time motor tuning procedure to optimize tool performance. Primarily applicable for 5 Nm, 10 Nm, and 15 Nm tools. (This must be done for all IQI4 Tools)
Note: Motor Brake Optimization is required only when upgrading from Application Version 1.0.0.282 or earlier. If Motor Brake Optimization has already been completed, the procedure does not need to be repeated.
Please follow the steps below to perform the Motor Brake Optimization.
- Turn ON the controller and log in.
- Check the Application Version of the controller
- Perform firmware upgrade as required:
- If the controller is on Application version 1.0.0.282, upgrade directly to 1.0.0.309.
- If the controller is on Application version earlier than 1.0.0.282, perform a two-step upgrade:
- Upgrade to 1.0.0.282
- Upgrade to 1.0.0.309
- Login to the controller after the upgrade is finished, and the controller has restarted.
- Navigate to:
System Maintenance → Firmware Upgrade → Update Type → Tool- Select file: Tool_20260525.etir
- Start the firmware update.
- After the update completes, a message will appear indicating: Motor Brake Optimization is required.
- Click OK.
- Hold the tool firmly in Hand or secure using a torque arm.
- Click Start when ready.
- The tool will automatically run in forward and reverse directions. (Do NOT press the trigger during this process)
- Wait until it finishes.
- Motor Brake Optimization is complete. The tool is now tuned and ready for use.
Controller Upgrade Instructions
SendSafely:
- Controller versions will be available to share from SendSafely platform from below link:
SendSafely Link: IQI SendSafely Link
Instructions: IR Tools Help - Updating Firmware
- Ensure to update both the controller firmware version and the tool firmware version
- If the controller is running a application version earlier than 1.0.0.282, a two-step upgrade is required:
- First upgrade to 1.0.0.282
- Then, upgrade to 1.0.0.309
Revision History
| Application Version | Date | Summary of Changes | Author |
| 1.0.0.254 | 8/13/2025 | New features and issue resolution | Swathi Murali |
| 1.0.0.265 | 10/14/2025 | New features and issue resolution | Swathi Murali |
| 1.0.0.273 | 12/08/2025 | New features and issue resolution | Swathi Murali |
| 1.0.17.0 (IQI2L Series)1.0.43.0 (IQI4L Series)1.0.0.282 | 1/29/2026 | Updated tool firmware versionNew features and issue resolution | Swathi Murali |
| 1.0.25.0 (IQI2L Series)1.0.52.0 (IQI4L Series)1.0.0.299 | 6/17/2026 | Updated tool firmware versionNew features and issue resolutionIntroduced a one-time Motor Brake Optimization for Motor Tuning | Swathi Murali |
| 1.0.0.309 | 11/18/2026 | New features and issue resolution | Swathi Murali |
Comments
0 comments
Please sign in to leave a comment.